Error messages – Panasonic AJ-HD150 User Manual

Page 87

Advertising
background image

– 87 –

Displaying the “HOURS METER” information

Turn the search dial to move the cursor ( * ). The description for the item where the cursor is located is shown on
the counter display.

Item No.

Item

Description

H00

OPERATION

H01

DRUM RUN

H02

TAPE RUN

H03

THREADING

H11

DRUM RUN r

H12

TAPE RUN r

H13

THREADING r

H30

POWER ON

<Notes>

The resettable items in the “HOURS METER” information are reset by the shop when performing maintenance or
other work.

The search buttons and the search dial cannot be operated while the DIAG menu is displayed.

If “T&S&M” is selected in the setup menu No. 006 (DISPLAY SEL), a message appears in the mode display
whenever a warning or error occurs. When multiple events occur, the event with the highest priority is displayed.

Priority

Display

Description

High

Error messages
(See error message table)

INT SG

NO INPUT

Warning messages
(See error message table)

Low

Warning messages

Priority

Monitor display

Description

VTR operation

High

FAN STOP

Operation continues

NO RF

Operation continues

SERVO NOT
LOCKED

Operation continues

LOW RF

Operation continues

HIGH ERROR

Operation continues

Low

RATE

Error messages

Displays the time that the power has been supplied in one-hour units.

Displays the time that the drum has been rotating in one-hour units.

Displays the time that the tape has been running during FF, REW, PLAY, SEARCH (JOG,
VAR, SHTL), REC, and EDIT modes (except for STILL in the JOG, VAR or SHTL mode) in
one-hour units.

The number of times for threading/unthreading is displayed in single units.

Displays the time that the drum has been rotating in one-hour units. (Can be reset)

Displays the time that the tape has been running during FF, REW, PLAY, SEARCH (JOG,
VAR, SHTL), REC, and EDIT modes (except for STILL in the JOG, VAR or SHTL mode) in
one-hour units. (Can be reset)

The number of times for threading/unthreading is displayed in single units. (Can be reset)

The number of times the power has been turned on is displayed in single units.

When an abnormal operation is detected in this unit, the AUTO OFF lamp lights up
and an error message is displayed.

This appears at the commencement (of the EE mode) for 2 seconds if the REC
button or EDIT button is pressed while the setup menu item No.600 (INT SG) has
been selected. Similarly, it appears for 2 seconds at the commencement of editing.

This appears at the commencement (of the EE mode) for 2 seconds if the REC
button or EDIT button is pressed when the quality of the signals—with the
exception of analog audio signals—which are input to the connector selected by the
INPUT SELECT switch is poor. Similarly, it appears for 2 seconds at the
commencement of editing.

When a warning occurs in this unit, the warning lamp lights up and a warning
message is displayed. When multiple warnings occur, the warning with the highest
priority is displayed.

This is displayed when the fan motor stops.

This appears when a blank part of the tape lasting for 1 or more
seconds has been detected during playback.
When all the following conditions have been met, it will be recognized
as a blank part.
· When no signals are output from any of the heads
· When the playback data cannot be read
· When CTL is not present

This is displayed when the servo is not locked for three or more
seconds during playback, recording, or editing.

This is displayed when envelope levels approximately 1/3 that of
normal levels are detected for more than one second during
playback, recording, or editing.

This is displayed when the error rate increases and correction/
interpolation is performed on either the video or audio playback signal.

Advertising