1 double click, 2 display, 1 double click 5.17.2.2 display – Psion Teklogix Vehicle-Mount Computer 8515 User Manual

Page 130

Advertising
background image

Chapter 5: Configuration
Scanner Settings Options Tab

110

Psion Teklogix 8515 Vehicle-Mount Computer User Manual

Figure 5.60 Scanner Settings Options

5.17.2.1 Double Click

Click Time (msec)

This parameter controls the maximum gap time (in milliseconds) for a double-click.
If the time between the first and second clicks of the scanner trigger is within this time, it is
considered a double-click. The allowable range is 0 to 1000. A value of zero disables
this feature.
A double-click produces different results depending on whether or not a value is assigned in
the ‘Click Data’ parameter. When a value is not assigned for the ‘Click Data’, double-click-
ing the scanner trigger overrides the target dot delay set in the ‘Dot Time’ parameter and ini-
tiates a normal scan sweep. If a value is assigned for the ‘Click Data’ parameter, double-
clicking the scanner trigger inserts the ‘Click Data’ value rather than initiating a scan.

Click Data

This parameter determines which character is sent to the application installed in your 8515
following a double-click. A dialog box appears, asking that you press the key you want to
insert. The ASCII/Unicode key value of the keypress is displayed.
Pressing the [ESC] key in this dialog box resets the data to zero.

5.17.2.2 Display

Scan Result

When this parameter is enabled, the type of bar code and the result of the scan appear on the
screen. Note that this information is only displayed after a successful decode and is visible
only while the scanner trigger is pressed. When the trigger is released, this information is
cleared from the screen.

Advertising