ACT2000 USER GUIDE

Certifications

North American Certifications

CSA Class I, Div 1, Group B, C, D; T4

European Directive Compliance (CE Mark)

EEx d, IIB+H

2

; T4

94/9/EC Potentially Explosive Atmospheres (ATEX) 08 ATEX 6108 X
(replaces 02ATEX6050X)
98/37/EC Machinery Directive
89/336/EEC Electromagnetic Compatibility Directive (EMC)

Materials

Housing

6061-T6 Anodized Aluminum

Conduit Union

Zinc Plated Steel

Extension Rod

17-4 PH CRES

Clevis

17-4 PH CRES

Seals

Nitrile, RTV and Teflon

Rod End Bearings

Aluminum Bronze

Connectors

Aluminum

Dimensions

5.2 in x 6.5 in x 16.7 in (ACT2000-590P)
6.0 in x 10.0 in x 12.9 in (ACT2000-200F)

Weight

35 lbs (ACT2000-590P)
50 lbs (ACT2000-200F)

1.3 Mechanical Installation

This section describes proper ACT2000 installation. Ensure compliance
with the factory recommendations.

Dimensions

The ACT2000 can be mounted with any directional orientation, whether
horizontal, vertical, or at an angle. Figures 1-1 and 1-3 show external
dimensions and mounting provisions for the pin-mount version of the
ACT2000. Figures 1-2 and 1-4 show external dimensions and mounting
provisions for the flange-mount version. Ensure that additional swing
clearance is factored into mounting calculations, as required.

WARNING

Lifting Hazard – Do not attempt to hand-lift the actuator. Use
appropriate lifting equipment.