2 general specification summary, Power input, General specification summary – Hamilton Sundstrand Company ACT2000 User Manual

Page 9

Advertising
background image

1.2 General Specification Summary

PARAMETER

VALUE

Power Input

Voltage Range

80-160 VDC; 120 VDC nominal

Maximum Current

20 A

Typical Transient Current

+20A < 60ms; +10A < 600ms; -5A < 100ms

Typical Continuous Current

< 1A

Inputs and Outputs

Discrete Inputs

RUN and RESET commands


ON Voltage:

12 – 32 VDC,

+24 VDC nominal @ 6.5 mA

OFF Voltage:

1.0 VDC, maximum

Discrete Outputs

FAULT & OVERTEMP alarms


OFF Voltage:

32 VDC maximum @ 150 µA typical

Effective ON Resistance

1.1 kΏ, nominal

@ ≥ 1.5 VDC:

Analog Input

DEMAND command signal

Current: 4 to 20 mA; 25 mA Maximum
Voltage: 5 VDC Maximum
Internal Impedance: 200 Ώ

Analog Outputs

POSITION & MTR

CURRENT feedback

Current: 4 to 20 mA
External Load Resistance: 300 Ώ, Maximum

Maximum Common Mode Voltage

±200 VDC User I/O to 120 VDC Return (less serial interface)

Performance

All performance values are based on use with ACT2000 in default
configuration. Any changes to ACT2000 firmware settings to change stroke
profile will alter performance values.

Maximum Velocity

10 in/sec

Maximum Continuous Force

500 lbf (100% Duty Cycle)

Maximum Peak Force

1000 lbf (100% Duty Cycle)

Maximum Stroke

5.9 in (ACT2000-590P, configuration dependent)
2.0 in (ACT2000-200F, configuration dependent)

Accuracy

± 1% Full Stroke

Mean Time Before Unscheduled Removal

30,000 Hours

Life Cycles

32,000 Minimum

Environmental

Temperature, Operating Ambient:

-40

° C (-40° F) to +93° C (+200° F)

Temperature, Storage

-40

° C (-40° F) to +125° C (+257° F)

Environmental Rating

Rated to CSA Type 3 and European IP65
Sealed against dust, protected against water

EMC

Meets EN 50081-2 and EN50082-2 for DC powered industrial equipment

Vibration

Meets Mil-Std-810E, Category 4 (5 – 2000 Hz)

INSTALLING THE ACT2000

3

Advertising