Signal Connections

Signals are sent between the ACT2000 and the user’s controller through
the integral 17-wire signal harness. The length of the signal harness is
90 inches. See Table 1-4 for the wire list for this harness. See Figure 1-8
for the system signal wiring diagram.

WIRE COLOR

FUNCTION

AWG

WHITE/ORANGE/YELLOW Serial/RX

In

20

WHITE/ORANGE/BLUE Serial/TX

Out

20

WHITE/ORANGE/GREEN Serial

RETURN

20

BLACK OVER

TEMP

Alarm

20

WHITE/BLACK

OVER TEMP Alarm RETURN

20

ORANGE FAULT

Alarm 20

WHITE/ORANGE

FAULT Alarm RETURN

20

VIOLET RUN

Command

20

WHITE/VIOLET

RUN Command RETURN

20

GRAY RESET

Command

20

WHITE/GRAY

RESET Command RETURN

20

BROWN Position

Demand

20

WHITE/BROWN

Position Demand RETURN

20

YELLOW Position

Feedback

20

WHITE/YELLOW

Position Feedback RETURN

20

BLUE Motor

Current

20

WHITE/BLUE

Motor Current RETURN

20

Table 1-4. Wire List for ACT2000 System Signal Harness