18

ACT2000 USER GUIDE

Discrete Outputs

The discrete outputs are +24 VDC. They are electrically isolated up to 500
VAC. See Figure 1-12 for a typical discrete output alarm connection.

CONTROLLER DISCRETE INPUT

ACT2000 DISCRETE OUTPUT

FAULT RTN

[WHT/ORN]

OVERTEMP RTN

[WHT/BLK]

FAULT ALARM

[ORN]

OVERTEMP ALARM

[BLK]

Figure 1-12. Typical Discrete Output Alarm Connection

RS232 Serial Communications Interface

Signal levels for the serial communications input and output are per
RS232 standards. See Figure 1-13 for a typical RS232 serial interface
connection. See Table 1-5 for computer COM port pin-outs for RS232.

COM 1

Tx

Rx

RTN

[WHT/ORN/BLU]

Tx

[WHT/ORN/YEL]

Rx

[WHT/ORN/GRN]

RTN

Tranceiver

ACT2000 RS232 INPUT / OUTPUT

COMPUTER

Figure 1-13. Typical RS232 Serial Interface Connection

FUNCTION

Standard 9-Pin

COM Port

Standard 25-Pin

COM Port

Transmit (Tx).

Pin 3

Pin 2

Receive (Rx)

Pin 2

Pin 3

Ground (GND)

Pin 5

Pin 7

Table 1-5. Computer COM Port Pin Outs