9

CH 1

CH 2

AUDIO

OUT

CH 1

CH 2

AUDIO

IN

REF VIDEO IN

VIDEO

IN

OUT

ON

OFF

75

TC IN

TC OUT

VIDEO MON

OUT

AUDIO

MON OUT

L

R

ENCODER

REMOTE

DC OUT

12V 250mA

AC IN

REMOTE

DC IN

SIGNAL

GND

FUSE 125V 2.5A

Connector areas

Parts and Their Functions

3 DC OUT socket

This is the DC 12V output connector.
It is used to supply power to the external remote
controller (model AJ-A95P).
The DC power cable is packed with the model AJ-
A95P controller.

4 Fuse holder

This contains a 2.5A fuse.

5 AUDIO MONITOR OUT (Lch/Rch) connectors

These are the output connectors for the audio
monitor signals. It is possible to select the channel
through which the audio monitor signals are to be
output using the audio monitor selector switch on
the front panel and setup menu item No.708.
(See page 36)

3

1

2

4

Pin No.

Signal

1

Ground

2

3

4

+12 V

1

2

3

4

Pin No.

Signal

1

Ground

2

3

4

+12 V

1 AC IN socket

This is the AC power inlet.
The accessory power cord is connected here.
Use an AC 120V (±10%) power supply to operate
this unit.
When the voltage has dropped to an extremely low
level, the unit’s power is automatically switched off.
It will take several minutes for the unit to be reset
even after the supply voltage is restored. In a case
like this, set the POWER switch to OFF, wait
several minutes, and start up the unit again. AC
power takes precedence when both AC and DC
power supplies have been connected.

2 DC IN socket

This is the input connector for the DC 12V power.
Use the optional AC adaptor (model AJ-B75).
When the voltage has dropped to around 10.6V, the
unit’s power is automatically switched off. It will
take several minutes for the unit to be reset even
after the supply voltage is restored. AC power
takes precedence when both AC and DC power
supplies have been connected.