background image

Printing Bar Codes

Page B-6

Bar Code Definition

The sequence used to define a horizontal bar code is

^BNxccc...c^G

^B

Two Character Sequence Identifier for
Horizontal Bar Code Definition.

N

Reserved Parameter.

x

Bar Code Type.
“a”

= Code 39 1:1:2:2 Ratio

“b”

= Code 39 1:1:3:3 Ratio

“c”

= Code 39 1:2:4:5 Ratio

“d”

= Code 39 LOGMAR Standard Density

“e”

= Code 39 LOGMAR Medium Density

“f”

= Code 39 LOGMAR Low Density

“g”

= 2-of-5 1:1:3:X Ratio

“h”

= 2-of-5 1:2:3:X Ratio

“i”

= Interleaved 2-of-5 BS Code 1:1:3:3 Ratio

“j”

= Interleaved 2-of-5 BS Code 1:2:4:5 Ratio

“k”

= Interleaved 2-of-5 BS Code 1.5:1.5:4.5:4.5 Ratio

“l”

= Interleaved 2-of-5 BS Code 2:2:6:6 Ratio

“m”

= Interleaved 2-of-5 C Code 1:1:2:2 Ratio

“n”

= Interleaved 2-of-5 C Code 1:1:2.5:2.5 Ratio

“o”

= Interleaved 2-of-5 C Code 1.5:1.5:3.5:3.5 Ratio

“p”

= Interleaved 2-of-5 C Code2:2:4.5:4.5 Ratio

ccc...c

Characters to be Bar Coded.

^G

Sequence Terminator.
Required to signal end of character data.

The width of a defined bar code is predetermined by the definition of the bar code
type. The width of all bars and spaces is automatically set.

Example:

The following sequence defines a Code 39 LOGMAR bar code of standard density.
The characters “12345” are encoded in the bar code.

^BNd12345^G^-

Example:

The same character data is represented below in a low density LOGMAR bar code.

^BNf12345^G^-