Primera Technology RX900 User Manual

Page 16

Advertising
background image

12

Label Stock

C. ADJUSTING THE LABEL STOCK

TOF

(TOP OF FORM)

SENSOR

If you are using label stock other than standard square /

rectangular diecut labels such as circular die-cut labels or

through-hole stock use the instructions below to adjust the

position of the label stock sensor. The sensor can be adjusted

using the slide bar on the inside of the printer. Below the slide

bar is a measurement which represents the distance between

the edge of the label stock and the sensor. Measure the

distance from the edge of the label stock to the correct position

on the stock. Set the sensor to this measurement.

Important Note: You must adjust the Stock Sensor before loading non-

standard label stock.

Circular Labels

If you are using Circular Labels you must adjust the Stock

sensor to correspond with the very top of the label where the

circles are closest together. If the sensor is too far to the right or

the left the printer will still sense the label but the image may

be offset downward because the printer will start printing at

the wrong position. If you are using stock that has multiple

labels across make sure the sensor corresponds to a place on

the stock that has a label and not a vertical gap.

0.5

1.0

1.5

2.0

12.7

25.4

38.1

50.8

mm

in.

Label Stock Sensor Slide

RX900.qxd 2/17/2011 1:27 PM Page 12

TOC

INDEX

Advertising