Maintenance and Troubleshooting

Planar PD7170 Installation/Operation Manual

67

PREL

IMINA

RY

Colors in the image are
swapped; for example,

reds appear blue or vice
versa.

• The Red/Pr, Green/Y or

Blue/Pb outputs from

the source are
connected to the

wrong inputs on the

PD7170.

• Ensure that the source

outputs are connected

to the correct PD7170
input.

LED is flashing alternating

green and red.

• The lamp cover is open.

• The lamp has failed or

exceeded its usage life.

• Close the lamp cover.

• Replace the lamp with

a new one.

LED is flashing red.

• PD7170 internal

temperature is too high.

• Power off the PD7170

and allow it to cool

down. Ensure that the

intake and exhaust
vents are not blocked.

Turn the projector back

on. If the problem
persists, please contact

Planar Technical

Support for assistance.

LED lights solid red.

• Fans are not working

properly or power-on
self-test has failed.

• Please contact Planar

Technical Support for
assistance.

Table 5-1. Troubleshooting Chart (continued)

Symptom

Possible Cause(s)

Solution