5 cautions on 8-bit timer/event counters – NEC PD78058FY(A) User Manual

Page 236

Advertising
background image

236

CHAPTER 9 8-BIT TIMER/EVENT COUNTERS

TI1, TI2, Input

CR10, CR20

TM1, TM2 Count Value

TO1, TO2

Interrupt Request Flag

00H

00H

00H

00H

00H

Count Pulse

TM1, TM2 Count Value

00H

01H

02H

03H

04H

Timer Start

9.5 Cautions on 8-Bit Timer/Event Counters

(1) Timer start errors

An error of one clock maximum may occur concerning the time required for a match signal to be generated

after timer start. This is because the 8-bit timer registers 1 and 2 (TM1 and TM2) are started asynchronously

with the count pulse.

Figure 9-14. 8-Bit Timer Registers Start Timing

(2) 8-bit compare register 10 and 20 setting

The 8-bit compare registers 10 and 20 (CR10 and CR20) can be set to 00H.

Thus, when these 8-bit compare registers are used as event counters, one-pulse count operation can be

carried out.

When the 8-bit compare register is used as 16-bit timer/event counter, write data to CR10 and CR20 after

setting bit 0 (TCE1) of the 8-bit timer mode control register 1 (TMC1) to 0 and stopping timer operation.

Figure 9-15. Event Counter Operation Timing