CHAPTER 15 D/A CONVERTER

0

7

0

6

DAM5 DAM4

4

0

3

2

1

0

FF98H

Address

DAM

Symbol

0

DACE1 DACE0

5

00H

After

Reset

R/W

R/W

DAM5

0

1

Normal mode

Real-time output mode

DACE0

0

1

D/A conversion stop

D/A conversion enable

DACE1

0

1

D/A conversion stop

D/A conversion enable

DAM4

0

1

Normal mode

Real-time output mode

D/A Converter Channel 0 Control

D/A Converter Channel 1 Control

D/A Converter Channel 0 Operating Mode

D/A Converter Channel 1 Operating Mode

15.3 D/A Converter Control Registers

The D/A converter mode register (DAM) controls the D/A converter. This register sets D/A converter operation

enable/stop.

The DAM is set with a 1-bit or 8-bit memory manipulation instruction.

RESET input sets this register to 00H.

Figure 15-2. D/A Converter Mode Register Format

Cautions 1. When using the D/A converter, a dual-function port pin should be set to the input mode, and

a pull-up resistor should be disconnected.

2. Always set bits 2, 3, 6, and 7 to 0.

3. When D/A conversion is stopped, the output state is high-impedance.

4. The output triggers are INTTM1 and INTTM2 for channel 0 and channel 1, respectively, in the

real-time output mode.