CHAPTER 14 A/D CONVERTER

14.5 A/D Converter Cautions

(1) Power consumption in standby mode

The A/D converter operates on the main system clock. Therefore, its operation stops in STOP mode or in

HALT mode with the subsystem clock. As a current still flows in the AV

REF0

pin at this time, this current must

be cut in order to minimize the overall system power dissipation. In Figure 14-9, the power dissipation can

be reduced by outputting a low-level signal to the output port in standby mode. However, there is no precision

to the actual AV

REF0

voltage, and therefore the conversion values themselves lack precision and can only be

used for relative comparison.

Figure 14-9. Example of Method of Reducing Current Consumption in Standby Mode

(2) Input range of ANI0 to ANI7

The input voltages of ANI0 to ANI7 should be within the specification range. In particular, if a voltage above

AV

REF0

or below AV

SS

is input (even if within the absolute maximum rating range), the conversion value for

that channel will be indeterminate. The conversion values of the other channels may also be affected.

Series Resistor String

AV

DD

AV

REF0

AV

REF0

=V

DD

AV

SS

Output Port

.

.

µ

PD78058F, 78058FY

AV

SS

Advertising