CHAPTER 23 STANDBY FUNCTION

STOP Mode Clear

X1 Pin
Voltage
Waveform

V

SS

a

23.1.2 Standby function control register

A wait time after the STOP mode is cleared upon interrupt request till the oscillation stabilizes is controlled with

the oscillation stabilization time select register (OSTS).

OSTS is set with an 8-bit memory manipulation instruction.

RESET input sets OSTS to 04H. However, it takes 2

17

/f

X

, not 2

18

/f

X

, until the STOP mode is cleared by RESET

input.

Figure 23-1. Oscillation Stabilization Time Select Register Format

Caution

The wait time when clearing the STOP mode does not include the time until clock oscillation

starts after the STOP mode is cleared (“a” in the figure below). This applies to STOP mode

clearance by RESET input as well as STOP mode clearance by interrupt request generation.

Remarks 1. f

XX

: Main system clock frequency (f

X

or f

X

/2)

2. f

X

: Main system clock oscillation frequency

3. MCS : Bit 0 of oscillation mode select register (OSMS)

4. Values in parentheses apply to operating at f

X

= 5.0 MHz

Address

FFFAH

04H

After

Reset

R/W

R/W

0

0

0

0

1

Selection of Oscillation Stabilization
Time when STOP Mode is Released

2

12

/f

xx

2

14

/f

xx

2

15

/f

xx

2

16

/f

xx

2

17

/f

xx

OSTS2

7

0

Symbol

OSTS

6

0

5

0

4

0

3

0

2

OSTS2

1

OSTS1

0

OSTS0

0

0

1

1

0

Other than above

OSTS1

MCS = 1

MCS = 0

2

12

/f

x

(819 s)

2

14

/f

x

(3.28 ms)

2

15

/f

x

(6.55 ms)

2

16

/f

x

(13.1 ms)

2

17

/f

x

(26.2 ms)

2

13

/f

x

(1.64 ms)

2

15

/f

x

(6.55 ms)

2

16

/f

x

(13.1 ms)

2

17

/f

x

(26.2 ms)

2

18

/f

x

(52.4 ms)

µ

0

1

0

1

0

OSTS0

Setting prohibited