1. Inspect Exterior Hoods at least once a month.

Make sure exhaust and fresh air supply hoods are not blocked or
restricted by leaves, grass, or snow. In winter, it is especially important
to make sure snow is not blocking the hoods or that frost has not built
up on the wire mesh (bird screen).

WARNING: Blockage of hoods may cause an imbalance.

2. Clean Air Filters - Twice a Year

The standard filters equipped with your HRV are removable and
washable.

a) simply open access door and slide core out

b) remove filter clips

c) once clips are removed filters can be taken off the core to be rinsed

with water or a combination of mild soap and water. Do not clean in

the dishwasher

d) to re-assemble, place clean filter(s) (wet or dry) back into their

positions against the core and return clips to their original position

e) slide core back into its original position

3. Clean Core - Twice a Year

a) open access door

b) carefully grip ends of core and pull evenly outward.

-core may be snug, but will slide out of the channel

c) once removed from the cabinet remove filters

d) wash core in warm soapy water

(do not use dishwasher)

e) install the clean filters

f) install clean core

Note: Core installation label on the outer end of the core.

To install the clean core:

a) first mount the bottom flange of the core guide into the bottom H

channel approximately 1/4” (6mm)

b) mount the left or right side flange of the core guide approximately

1/4” (6mm) followed by the other side

c) mount the top flange of the core guide into the top H channel

approximately 1/4” (6mm)

d) with all four corners in place and the core straight and even, push

hard in the center of the core until the core stops on the back of the

cabinet

NOTE: Core will appear to stick out from cabinet approximately 1/8”
(3mm). This is designed this way so that the access door will fit tight
against the core.

4. Motors - Maintenance Free

5. Drain (condensate) Line - Clean Once a Year

Inspect drain line, drain spout and “P” trap for blockage, mold or kinks.
Flush with warm soapy water and replace if worn, bent or unable to
clean.

6. Clean Duct System if Required

The duct system running to and from the HRV may accumulate dirt.
Wipe and vacuum the duct once every year. You may wish to contact a
Heating/Ventilation company to do this.

7. General Maintenance - Twice a Year

Wipe down the inside of the cabinet with a damp cloth to remove dirt,
bugs and debris that may be present.

8. Cleaning the Fans

Fans may accumulate dirt causing an imbalance and/or excessive
vibration of the HRV. A reduction in the air flow may also occur. In
new construction this may result within the first year due to heavy dust
and may occur periodically after that over time depending on the
outdoor conditions.

• unplug the HRV and open the service door

• remove the core

• remove ducting (metal and/or flexible insulated type) from the red

and/or blue ports which are connected immediately inline with the

fan assembly

• use a small brush, such as a toothbrush or pipe

cleaner, and insert first

(a) through the large opening of the fan assembly and then

(b) through the smaller opening in the end of the fan assembly

• scrub individual fan blades until clean. Avoid moving or damaging

balancing flat weight, clip is usually found on one or more of the fan

blades

• vacuum and wipe

• reassemble making sure ducting is reattached firmly and insulation

and moisture barrier are sealed and taped

Before attempting this task, thought should be given to having a
qualified service technician complete the service work.