Lifebreath RNC120D User Manual

Page 4

Advertising
background image

4

RNC95 Specifications
The RNC95 HRV (Heat Recovery Ventilator) has been designed
to allow the installer to choose between two possible positions
on the cabinet for the Stale Air Exhaust (from building) port.
Illustrations in this manual show standard (side mounted) port
location. The same specifications apply to both RNC95 setups,
regardless of which port position is selected.

Variable Port Location / Installation

(Model RNC95 only)
The exhaust return port collar is not factory installed. Installer
may choose either side mounted or alternate top mounted port
by simply removing one of the two knock-out plates and
attaching a port collar (supplied). To remove knock-out plate,
insert a utility knife into the knock-out slits and trace them
completely to puncture protective film underneath. Then, cut the
solid tabs between the slits, using tin snips or side cutters, and
remove the knock-out plate. If any protective film still blocks
the opening, remove it now.

In order to make the RNC95 as space efficient as possible, the
INDOOR supply and return ports are converted from round to
oval shape. Overall size of the port remains the same. Simply
bend a standard duct fitting to the correct shape, and attach to
the oval port using the same method as for a round port.

RNC95 Air Flow
Stale air enters the FRONT RIGHT side port. The air will pass
down the front half of the core, then up the back half of the core
and out the RIGHT REAR port.

Fresh outdoor air will enter the LEFT REAR port and pass down
the back half of the core. It will then pass up the front half of the
core, and out the LEFT FRONT port.

SIDE MOUNTED PORT

TOP MOUNTED PORT

standard location

alternate location

Round port bent to oval

Port Configuration and Airflow

Model RNC95