NEC NP40 User Manual

Page 57

Advertising
background image

49

3. Loosen the two screws securing the lamp housing until the phillips screwdriver goes into a freewheel-

ing condition.

The two screws are not removable.

Remove the lamp housing by holding the handle.

6. Maintenance

NOTE: There is an interlock on this case to prevent the risk of electrical shock. Do not attempt to circumvent this interlock.

4. Push the part as shown on the drawing and insert a new lamp housing until it is plugged into the socket.

CAUTION

Do not use a lamp other than the NEC replacement lamp NP03LP (NP60) or NP02LP (NP50/NP40).
Order this from your NEC dealer.

Secure it in place with the two screws.

NOTE: Tighten the two screws alternately until both screws are completely tightened. Failure to do this can result in air leak
from the cooling pump, causing the pump error. (

page

52

)

1

2

Interlock

5. Reattach the lamp cover.

Tighten the lamp cover screw.

Be sure to tighten the screw.

Advertising