52

7. Appendix

Troubleshooting

This section helps you resolve problems you may encounter while setting up or using the projector.

Indicator Messages

Power Indicator

Status Indicator

Lamp Indicator

Over-Temperature Protection

If the temperature inside the projector rises too high, the over-temperature protector will automatically turn off the lamp with
the STATUS indicator blinking (2-cycle On and Off.)
Should this happen, do the following:

- Unplug the power cable after the cooling fans stop.
- Move the projector to a cooler location if the room where you are presenting is particularly too warm.
- Clean the ventilation holes if they are clogged with dust.
- Wait about 60 minutes until the inside of the projector becomes cool enough.

Indicator Condition

Projector Condition

Note

Off

The main power is off

Blinking light

Green

0.5 sec On,
0.5 sec Off

The projector is getting ready
to turn on.

Wait for a moment.

2.5 sec On,
0.5 sec Off

Off Timer is enabled.

Orange

0.5 sec On,
0.5 sec Off

T h e p r o j e c t o r i s c o o l i n g
down.

Wait for a moment.

Steady light

Green

The projector is turned on.

Orange

The projector is in Standby.

Indicator Condition

Projector Condition

Note

Off

Normal

Blinking light

Red

1 c y c l e ( 0 . 5 s e c
On, 2.5 sec Off)

L a m p c o v e r e r r o r o r l a m p
housing error

Replace the lamp cover or lamp housing correctly.

2 c y c l e ( 0 . 5 s e c
On, 0.5 sec Off)

Temperature error

The projector is overheated. Move the projector to a
cooler location.

3 c y c l e ( 0 . 5 s e c
On, 0.5 sec Off)

Power error

Power unit is not working properly. Cont ac t your
dealer.

4 c y c l e ( 0 . 5 s e c
On, 0.5 sec Off)

Fan error

Fans will not work correctly.

6 c y c l e ( 0 . 5 s e c
On, 0.5 sec Off)

Lamp error

Lamp fails to light. Wait a full minute and then turn on
again.

8 c y c l e ( 0 . 5 s e c
On, 0.5 sec Off)

Cooling pump error

• The two screws on the lamp housing are not com-

pletely tightened. Tighten the two screws alternately
until both screws are completely tightened.

• The cooling pump is not working properly. Contact

your dealer.

Green

Re-firing the lamp (The pro-
jector is cooling down.)

The projector is re-fi ring.
Wait for a moment.

Steady light

Orange

Control Panel Lock is on.

You have pressed cabinet button when Control Panel
Lock is on.

Indicator Condition

Projector Condition

Note

Off

Normal

Blinking light

Red

Lamp has reached its end of life. Lamp
replacement message will be displayed.

Replace the lamp.

Steady light

Red

Lamp has been used beyond its limit.
The projector will not turn on until the
lamp is replaced.

Replace the lamp.

Green

Lamp mode is set to Eco mode.

Advertising