Appendix, 1) troubleshooting, Indicator messages – NEC NP-P350X User Manual

Page 210: 1 troubleshooting, Over-temperature protection

Advertising
background image

192

9. Appendix

1 Troubleshooting

This section helps you resolve problems you may encounter while setting up or using the projector.

Indicator Messages

Power Indicator

Indicator Condition

Projector Condition

Note

Off

The main power is off

Blinking light

Blue

0�5 sec On,

0�5 sec Off

The projector is getting ready to turn on�

Wait for a moment�

2�5 sec On,

0�5 sec Off

Off Timer is enabled�

Steady light

Blue

The projector is turned on�

Orange

[NORMAL] is selected for [STANDBY MODE]

Red

[POWER-SAVING] is selected for [STANDBY

MODE]

Status Indicator

Indicator Condition

Projector Condition

Note

Off

Normal or Standby ([POWER-SAVING] for

[STANDBY MODE])

Blinking light

Red

1 cycle (0�5 sec

On, 2�5 sec Off)

Lamp cover error or lamp housing error

Replace the lamp cover or lamp housing correctly�

2 cycle (0�5 sec

On, 0�5 sec Off)

Temperature error

The projector is overheated� Move the projector to

a cooler location�

3 cycle (0�5 sec

On, 0�5 sec Off)

Power error

Power unit is not working properly� Contact your

dealer�

4 cycle (0�5 sec

On, 0�5 sec Off)

Fan error

Fans will not work correctly�

6 cycle (0�5 sec

On, 0�5 sec Off)

Lamp error

Lamp fails to light� Wait a full minute and then turn

on again�

9 cycle (0�5 sec

On, 0�5 sec Off)

[DYNAMIC CONTRAST] error

Dynamic Contrast function is not working properly�

Contact your dealer�

Orange 1 cycle (0�5 sec

On, 2�5 sec Off) Network conflict

Both the built-in wired LAN and the wireless LAN can-

not be connected to the same network at the same

time�

To use both built-in wired LAN and wireless LAN at

the same time, connect them to different networks�

Green

Re-firing the lamp (The projector is cooling

down�)

The projector is re-firing�

Wait for a moment�

Steady light

Green

Standby ([NORMAL] for [STANDBY MODE])

Orange

CONTROL PANEL LOCK is on�

You have pressed cabinet button when Control

Panel Lock is on�

CONTROL ID error

Remote control ID and projector ID are not

matched�

Lamp Indicator

Indicator Condition

Projector Condition

Note

Off

Normal

Blinking light

Red

Lamp has reached its end of life� Lamp replace-

ment message will be displayed�

Replace the lamp�

Steady light

Red

Lamp has been used beyond its limit� The projector

will not turn on until the lamp is replaced�

Replace the lamp�

Green

[ECO MODE] is set to [AUTO ECO], [ECO1], or

[ECO2]

Over-Temperature Protection

If the temperature inside the projector rises too high, the over-temperature protector will automatically turn off the lamp
with the STATUS indicator blinking (2-cycle On and Off.)
Should this happen, do the following:
• Unplug the power cord after the cooling fans stop.
• Move the projector to a cooler location if the room where you are presenting is particularly too warm.
• Clean the ventilation holes if they are clogged with dust.
• Wait about 60 minutes until the inside of the projector becomes cool enough.

Advertising