OUTPUT_SET ALL OFF

Set all outputs OFF

OUTPUT_INVERT ALL

Inverts all outputs

OUTPUT PULSE ALL ON
*

All outputs pulse ON *

OUTPUT_PULSE ALL
OFF *

All outputs pulse OFF *

INPUT_GET x

Return a voltage of input x, x = pin number 1-11

INPUT_GET ALL

Return states of all inputs

INPUT_GET_CHANGE x

Subscribe a voltage limit alarm of input x, x = pin number 1-
11

INPUT_GET_CHANGE
ALL

Subscribe a input state change of all inputs

INPUT CHANGE CANCEL
x

Cancel input x subscription, x = pin number 1-11

INPUT CHANGE CANCEL
ALL

Cancel all input subscriptions

CHANGE_PWORD

Change password

OUTPUT PULSE CANCEL
x

Cancel output x pulse, x = pin number 1-9

OUTPUT PULSE CANCEL
ALL

Cancel all outputs

LOCATION_GET

Get location information **

* The duration of the pulse will be added to the control message after the corresponding command. The format is the
following:

Output_Pulse 1 On <days>d<hours>h<minutes>m<seconds>s

for example Output_Pulse 1 On 5m30s

For more information about pulse commands, see Chapter 9.3.7.

** The location support needs external GPS device to be connected to the Nokia 12 GSM Module. The Nokia 12
GSM Module supports NMEA-0183 protocol.

9.2 STATUS

MESSAGES

The Nokia 12 GSM Module supports the status messages listed in

Table 5. You can define an alias for each of them. The messages will be sent
as responses to device query control messages according to the current
command and device state.