4-10 Riverstone Networks RS 2100 Switch Router Getting Started Guide

Setting the Basic System Information

RS 2100 Initial Configuration

Here is an example:

5.

Use the

interface add ip

command to set the IP address and netmask for the en0 Ethernet

interface. The en0 Ethernet interface is used by the RS 2100’s management port.

Here is an example:

Note

The en0 interface is automatically created by the system and is reserved for the
RS 2100’s management port.

6.

To activate the system commands entered in the previous steps, use the following command:

The CLI displays the following message:

7.

Enter “

y

” to activate the changes.

8.

To display the Active configuration, exit the Configuration mode, then enter the following
command:

Here is an example:

rs(config)#

system set name "

rs

"

rs(config)#

system set location "Houston, TX"

rs(config)#

system set contact "John Smith"

rs(config)#

interface add ip en0 address-netmask 16.50.11.22/16

save active

Do you want to make the changes Active? [y]

system show active-config

rs#

system show active-config

Running system configuration:

!

! Last modified from Console on Mon Jan 25 11:55:35 2001

!

1 : system set name "rs"

2 : system set location "Houston, TX"

3 : system set contact "John Smith"