Warning – Roberts Gorden Combat UHD[X][S][R] 75 User Manual

Page 41

Advertising
background image

SECTION 14: R

EPLACEMENT

P

ARTS

35

SECTION 14: REPLACEMENT PARTS

Burner Components
All serviceable burner parts are accessed by the
door on the side of the heater. Remove the
sheetmetal screws.

14.1 Gas Valve
Remove the gas supply pipe at the heater inlet.

Follow steps in Section 14.2 and Section 14.2.1 to
remove gas valve/manifold.
Replace in reverse order. Verify that the gas flow
direction of the valve is correct. Use a minimum
amount of gas seal on the thread joint. Check that
all the joints are leak free. Reset gas valve. See
Page 25, Section 10.2.2
.

IT IS IMPORTANT THAT ONLY THE CORRECT
GAS VALVE IS USED WHEN REPLACING
THESE CONTROLS.

See warnings and notes on Page 28, Section 12
before removing or replacing parts.

WARNING

Explosion Hazard

Installation, service and annual inspection
must be done by a contractor qualified in
the installation and service of gas-fired
heating equipment or your gas supplier.

Turn off gas and electrical supplies before
performing service or maintenance.

Failure to follow these instructions can
result in death, injury or property damage.

½PSI

IN

C

ON

OFF

Flexible Air Duct

NOTE: Separated combustion

Description

Part Number

Gas Valve, NG (Models UHD[X][S][R] 75 - 125)

90032505

Gas Valve, LP (Models UHD[X][S][R] 75 - 125)

90032506