Warning – Roberts Gorden Combat UHD[X][S][R] 75 User Manual

Page 9

Advertising
background image

SECTION 3: C

RITICAL

C

ONSIDERATIONS

3

SECTION 3: CRITICAL CONSIDERATIONS
3.1 Basic Information
UHD[X][S][R] heaters have automatic ignition
burners for ON/OFF operation only.

3.2 Manufactured Units
Gas-fired, power-vented duct furnace with tubular
heat exchanger. Units shall have a minimum of 82%
thermal efficiency. The standard unit shall consist of
a non-separated combustion design with an
aluminized heat exchanger. Design and heat
exchanger alternatives shall be offered as follows:

• Separated Combustion: A separated

combustion unit shall feature an enclosed,
sealed burner box. A piece of flexible air duct
connects this burner box to a flange on the
cabinet. Combustion air should be ducted from
outside the heated space, with the ductwork
connecting to the unit with the use of the flange.

• Stainless Steel Heat Exchanger: A stainless

steel heat exchanger unit shall consist of heat
exchanger tubes, heat exchanger tube supports,
heat exchanger tube plates and vent box
produced of 409 stainless steel.

3.3 Location and Suspension
All models:

• Must be installed indoors.

• Must be installed on the positive pressure side of

the air circulation blower.

• Must be installed in a level position with

horizontal discharge.

• May be mounted on a shelf of non-combustible

material using shelf mounting brackets.(See
Page 9, Figure 4
and Page 9, Figure 5 for
details.)

• May be suspended from above (See Page 8,

Figure 3) or from wall brackets of sufficient
strength to support the heater as listed in the
Dimension Data Table on Page 40, Section 15.1.

• Must be installed in a manner which allows

access to all serviceable components. See Page
3, Figure 1
for details.

3.4 Minimum Required Installation Clearances
Clearances around the heater and vent must be as
indicated on Page 3, Figure 1 and Page 13, Figure 6
through Page 16, Figure 11 to ensure access for
servicing, and correct operation.

3.5 Clearances to Combustibles

Clearances must be as indicated on Page 3, Figure
1
. If clearances to combustibles are not indicated,
then installation clearances apply.

Figure 1: Clearances to Combustibles

WARNING

Fire Hazard

Some objects can catch fire or explode

when placed close to heater.

Keep all flammable objects, liquids and

vapors the required clearances to

combustibles away from heater.

Failure to follow these instructions can

result in death, injury or property damage.

Clearance to Vent: 2" (5 cm)

*18" (46 cm) minimum is necessary for
servicing.