1 general cabling guidance, Cable types and length, Routing cables – Raymarine C90w User Manual

Page 22: Strain relief, Circuit isolation, Cable shielding

Advertising
background image

3.1 General cabling guidance

Cable types and length

It is important to use cables of the appropriate type and length

• Unless otherwise stated use only standard cables of the correct

type, supplied by Raymarine.

• Ensure that any non-Raymarine cables are of the correct quality

and gauge. For example, longer power cable runs may require
larger wire gauges to minimize voltage drop along the run.

Routing cables

Cables must be routed correctly, to maximize performance and
prolong cable life.

• Do NOT bend cables excessively. Wherever possible, ensure a

minimum bend radius of 100 mm.

Minimum bend of cable
100 mm (4 in) radius

Minimum bend
200 mm (8 in)
diameter

• Protect all cables from physical damage and exposure to heat.

Use trunking or conduit where possible. Do NOT run cables
through bilges or doorways, or close to moving or hot objects.

• Secure cables in place using tie-wraps or lacing twine. Coil any

extra cable and tie it out of the way.

• Where a cable passes through an exposed bulkhead or deckhead,

use a suitable watertight feed-through.

• Do NOT run cables near to engines or fluorescent lights.

Always route data cables as far away as possible from:

• other equipment and cables,

• high current carrying ac and dc power lines,

• antennae.

Strain relief

Ensure adequate strain relief is provided. Protect connectors from
strain and ensure they will not pull out under extreme sea conditions.

Circuit isolation

Appropriate circuit isolation is required for installations using both
AC and DC current:

• Always use isolating transformers or a separate power-inverter

to run PC’s, processors, displays and other sensitive electronic
instruments or devices.

• Always use an isolating transformer with Weather FAX audio

cables.

• Always use an RS232/NMEA converter with optical isolation on

the signal lines.

• Always make sure that PC’s or other sensitive electronic devices

have a dedicated power circuit.

Cable shielding

Ensure that all data cables are properly shielded that the cable
shielding is intact (e.g. hasn’t been scraped off by being squeezed
through a tight area).

22

C-Series Widescreen installation

Advertising