6.3 Radar troubleshooting

Problems with the radar and their possible causes and solutions
are described here.

Problem

Possible causes

Possible solutions

Check that the scanner
power supply cable
is sound and that all
connections are tight
and free from corrosion.

Check relevant fuses
and breakers.

Radar scanner power
supply.

Check power source is
of the correct voltage
and sufficient current
(using voltage booster if
appropriate).

Check that the Scanner
is correctly connected
to the display via a
cross over coupler or
SeaTalk

hs

switch.

Check the status of the
SeaTalk

hs

Switch.

SeaTalk

hs

network

problem.

Check that SeaTalk

hs

cables are free from
damage.

Software mismatch
between equipment may
prevent communication.

Contact Raymarine
technical support.

No Data or No scanner
message.

Switch at scanner
pedestal in OFF position.

Ensure scanner
pedestal switch is in
ON position.

Troubleshooting

61