Installation checklist, Operating the storage tank – Rheem Marathon Thermal MTS105200 User Manual
Page 10
Installation Checklist
A. Storage tank Location
B. Water Supply
C. Relief Valve
❑
Close to area of heated water demand.
❑
Indoors and protected from freezing
temperatures.
❑
Area free of flammable vapors.
❑
Provisions made to protect area from
water damage.
❑
Sufficient room to service unit.
❑
Storage tank completely filled with
water.
❑
Air purged from storage tank and piping.
❑
Water connections tight and free of leaks.
❑
Temperature and Pressure Relief Valve
properly installed and discharge line run
to open drain.
❑
Discharge line protected from freezing.
10
Safety Precautions
This storage tank will not control the
water temperature.
Maximum operating temperature of
water in tank = 170
° F
.
Temperature & Pressure Safety Relief
valve opens at: 210° F, and/or 150
PSI..
Maximum flow rate permissible
through ports on side wall of tank =
20 GPM.
Operating the storage tank.