Installing the storage tank, Temperature and pressure relief valve, Vacuum relief valve – Rheem Marathon Thermal MTS105200 User Manual

Page 6: Drain pan

Advertising
background image

6

A  new  combination  temperature  and  pressure  relief  valve,  complying  with  the  Standard  for  Relief  

Valves  and  Automatic  Gas  Shut-­Off  Devices  for  Hot  Water  Supply  Systems,  ANSI  Z21.22,  is  supplied  

and  must  be  installed  in  the  opening  provided  and  marked  for  the  purpose  on  the  storage  tank.  No  

valve  of  any  type  should  be  installed  between  the  relief  valve  and  the  tank.  Local  codes  shall  govern  the  

installation  of  relief  valves.

!

WARNING:  The  

pressure  rating  of  the  

relief  valve  must  not  

exceed  150  PSI,  the  

maximum  working  

pressure  of  the  storage  

tank  as  marked  on    

the  rating  plate.  

Temperature  and  Pressure  Relief  Valve

Connect  the  outlet  of  the  relief  valve    

to  a  suitable  open  drain  so  that  the  

discharge  water  cannot  contact  live  

electrical  parts  or  persons  and  to  

eliminate  potential  water  damage.  
Piping  used  should  be  of  a  type  

approved  for  hot  water  distribution.  

The  discharge  line  must  be  no  smaller  

than  the  outlet  of  the  valve  and  must  

pitch  downward  from  the  valve  to  

allow  complete  drainage  (by  gravity)  

of  the  relief  valve  and  discharge  line.  

The  end  of  the  discharge  line  should  

not  be  threaded  or  concealed  and  

should  be  protected  from  freezing.  

No  valve  of  any  type,  restriction  or  

reducer  coupling  should  be  installed  in  

the  discharge  line.

Vacuum  Relief  Valve

NOTICE:    Do  NOT  

remove  or  tamper  with  

the  vacuum  relief  valve  for  

any  reason.    Doing  so  will  

void  the  manufacturer’s  

warranty.

The  vacuum  relief  valve,  which  must  

be  used  when  installing  the  storage  

tank,  is  factory  installed.
The  cold  water  inlet  has  a  vacuum  

relief  valve  installed.    Certain  

conditions  in  the  field  may  produce  a  

vacuum  or  negative  pressure  condition  

inside  the  storage  tank.    This  negative  

pressure  can  cause  the  tank  to  fail.    

The  vacuum  relief  valve  provides  

a  means  to  eliminate  the  negative  

pressure  or  vacuum  by  admitting  air  

into  the  tank  to  equalize  the  pressure.
It  is  not  recommended  to  pull  a  

vacuum  on  the  unit.
If  a  vacuum  is  pulled  on  the  unit,  

refer  to  the  "To  Fill  the  Storage  tank"  

section  to  ensure  the  unit  is  full  of  

water  before  operating.

Installing  the  storage  tank.

NOTICE:  Auxiliary  

catch  pan  MUST  

conform  to  local  

codes.

The  storage  tank  should  not  be  

located  in  an  area  where  leakage  of  

the  tank  or  connections  will  result  in  

damage  to  the  area  adjacent  to  it  or  

to  lower  floors  of  the  structure.  It  is  

recommended  that  a  suitable  catch  

pan,  adequately  drained,  be  installed  

under  the  storage  tank.
Catch  pan  kits  are  available  from  

the  store  where  the  storage  tank  

was  purchased,  or  any  water  heater  

distributor.
Under  no  circumstance  will  the  

manufacturer  be  held  liable  for  any  

water  damage  in  connection  with  this  

storage  tank.

■■■✦■■■

B

A

To  open  drain,  this  line  should  be  at  least  3/4

s  ID  and  

pitched  for  proper  drainage.

B  =    Max  2

s

A  =    Diameter  of  

storage  tank  
plus  2

s  min.

Drain  Pan