Water supply connections -­ top of storage tank, Water connection ports – on sidewall of unit – Rheem Marathon Thermal MTS105200 User Manual

Page 7

Advertising
background image

7

Water  Supply  Connections  -­  Top  of  Storage  Tank

Refer  to  the  illustration  on  next  page  

for  suggested  typical  installation.  

The  installation  of  unions  or  flexible  

copper  connectors  is  recommended  

on  the  hot  and  cold  water  connections  

so  that  the  storage  tank  may  be  

easily  disconnected  for  servicing  if  

necessary.  The  HOT  and  COLD  water  

connections  are  clearly  marked  and  

DUHƎ137RQDOOPRGHOV,QVWDOOD

shut-­off  valve  in  the  cold  water  line  

near  the  storage  tank.
The  cold  water  connection,  hot  water  

connection,  and  the  temperature  

and  pressure  relief  valve  may  be  

temporarily  disconnected  from  the  unit  

to  ease  installation  by  loosening  the  

union  hex  nuts  connecting  the  fittings  

to  the  storage  tank.    The  connection  of  

these  parts  to  the  unit  use  seal  rings  to  

form  a  water  tight  connection.    Re-­use  

the  rubber  seal  rings  that  are  provided  

with  the  heater  when  re-­installing  

the  components.    Do  NOT  use  pipe  

sealant  on  this  joint.    Do  NOT  torque  

the  union  hex  nuts  to  over  35  ft-­lbs  

when  reinstalling  the  components.    

Failure  to  properly  reconnect  the  

fittings  provided  with  the  storage  tank  

will  void  the  manufacturer’s  warranty.
SOLDER  WITH  CARE!!!    If  sweat  

connections  are  used,  do  NOT  apply  

heat  directly  to  any  component  

directly  connected  to  the  storage  

tank.    This  includes  the  cold  water  

connection,  hot  water  connection,  

temperature  and  pressure  relief  valve  

and  the  drain  valve.    Doing  so  will  

damage  the  storage  tank  beyond  repair  

and  void  the  manufacturer’s  warranty.  

NOTICE:    Do  not  

attempt  to  turn  any  

fitting  connected  

to  the  storage  tank  

union  hex  nuts  that  

are  tightened.    Doing  

so  will  damage  the  

storage  tank  and  void  

the  manufacturer’s  

warranty.

To  Fill  the  Storage  tank

Make  certain  the  drain  valve  is  

completely  closed.  
Open  the  shut-­off  valve  in  the  cold  

water  supply  line.
Open  each  hot  water  faucet  slowly  to  

allow  the  air  to  vent  from  the  storage  

tank    and  piping.  
A  steady  flow  of  water  from  the  hot  

water  faucet(s)  indicates  a  full  storage  

tank.

Water  Connection  Ports  –  On  Sidewall  of  Unit

Two  water  connection  ports  are  

located  on  the  sidewall  of  the  tank.    

These  ports  have  1-­1/4”  female  NPT  

fittings.  (tapered  pipe  thread).
Teflon  pipe  tape  or  “dope”  are  

recommended  for  these  two  

connections.
Fittings  must  be  held  securely  (and  not  

turn)  during  tightening  /  installation  /  

removal.    Failure  to  do  so  may  result  

in  catastrophic  damage  to  the  storage  

tank.    
It  is  recommended  that  a  threaded  

union  be  installed  near  the  tank.
Maximum  flow  rate  through  ports  is  

20  GPM.