Rugged Outback RS416 User Manual

Page 20

Advertising
background image

20

2008 RuggedCom Inc. All rights reserved

Rev104

4.5 Console Port Wiring


A RS232 console port for configuration and management of the device is located on the LED
display module shown in Figure 13. This port is intended to be a temporary connection during initial
configuration or troubleshooting and allows for direct access to the serial-based management
console. The connection is made using the DB9-Female to RJ45 console cable included in the
device packaging shown below. Console connection settings are 57600 baud, no parity bits, 8 data
bits, and 1 stop bit.

Figure 13: Console port location on display board

Figure 14: Console cable


For user reference, the console cable pin-out is show in the table below.

RuggedCom RS232 over RJ45 pin-out specification

Signal Name (PC is DTE)

Female DB9

Male RJ45

DCD – Carrier detect

1

2

TxD – Transmit Data

2

5

RxD – Receive Data

3

6

DTR – Data terminal ready

4

3

Signal GND

5

4

DSR – Data set ready

6

1*

RTS – Ready to send

7

8

CTS – Clear to send

8

7

RI – Ring Indicator

9

1*

Table 4: RS232 over RJ45 console cable pin-out


After initial configuration, the RS416 can be configured via a number of mechanisms such as
Telnet, and the built-in web server. Consult the RuggedSwitch ROS User Guide for further details.

NOTE: This port is not intended to be a permanent connection and the cable shall be less than 2m
(6.5 ft) in length.

Advertising