5 Technical Specifications

5.1 Power Supply Specifications

Input Range

Power Supply

Type

Min

Max

Fuse

Rating

Max. Power Consumption

3

12 – 24 VDC

10 VDC

36 VDC

6.3A(F)

2

24 VDC

18 VDC

36 VDC

5A(F)

2

48 VDC

36 VDC

59 VDC

2A(T)

2

HI (125/250 VDC)

1

HI (110/230 VAC)

1

88 VDC
85 VAC

300 VDC
265 VAC

2A(T)

1,2

15 W

Table 7: Power Supply Specifications

NOTES:

1.

This is the same power supply for both AC and DC.

2.

(F) Denotes fast-acting fuse, (T) denotes time-delay fuse

3.

Power consumption varies based on configuration. 10/100Tx ports consume roughly 1W

less than fiber optic ports

4.

For continued protection against risk of fire, replace only with same type and rating of fuse.

5.2 Failsafe Relay Contact Ratings

Parameter

Value (Resistive Load)

Max Switching Voltage

240VAC, 125VDC

Rated Switching Current 2A @ 240VAC

0.15A @ 125VDC, 2A @ 30VDC

Max Switching Capacity

150W, 500VA

Table 8: Failsafe Relay Contact Ratings