4.6.2 RS232/RS485/RS422 via DB9


Each port is individually selectable via software to be RS232, RS485 or RS422. The DB9 port and
pin-out is shown below.

Figure 16: DB9 Female DCE Port pin-out

Pin

RS232 Mode

RS485 Mode

RS422 Mode

1

CD

-

-

2

TX

TX/RX+

TX+

3

RX

-

RX+

4

DTR

-

-

5

Common (Isolated Ground)

6

DSR

-

RX-

7

CTS

TX/RX -

TX-

8

RTS

-

9

RI

(No Connection)

-

-

Shield

Chassis Ground

Table 5: DB9 Female DCE Port pin-out

NOTES:
1.

No internal termination is provided.

2.

Pins 1, 4, and 6 are connected internally. Pins 7 and 8 are connected internally. The pins are

permanently asserted to 5V so that DTE devices that require DCD, DTR, or CTS signals will
operate. However, hardware flow control via RTS is not recognized.

3.

The Common terminals are optically isolated; however, there is transient voltage protection

circuitry between the Common terminals and chassis ground.