Setup, 1 flowchart of starting up the emulator – Renesas Emulation Probe M30850T2-EPB User Manual

Page 19

Advertising
background image

M30850T2-EPB User’s Manual

2. Setup

REJ10J1005-0200 Rev.2.00 April 1, 2007

2. Setup

This chapter describes the preparation for using this product, the procedure for starting up the emulator and how to change

settings.

2.1 Flowchart of Starting Up the Emulator

The procedure for starting up the emulator is shown in Figure 2.1. For details, refer to each section hereafter. And, when the

emulator does not start up normally, refer to “5. Troubleshooting” (page 90).


Check the package components.

Refer to “1.1 Package Components (page 13).


User registration

Refer to “User Registration” (page 11).


Install the M32C PC7501 Emulator Debugger

or M3T-PD308F.

Install the M32C PC7501 Emulator Debugger or M3T-PD308F for
this product.


Connect the host machine.

Connect the PC7501 to the host machine with the LPT parallel
interface cable, USB interface cable or LAN interface cable.
Set the interface selection switch on the panel of the PC7501 to the
using interface.


Connect the power supply for the emulator.

Connect a power supply for the emulator.


Connect the user system.

Connect the user system as occasion demands.


Turning on the power supply.

Turn ON the power to the emulator and the user system as
simultaneously as possible.


Check the LED display of the emulator.

Check that the system status LED, and POWER CLOCK, RESET
and WARNING of target status LED are lighting. When the user
system is not connected, the POWER LED does not light up.


Start up the emulator debugger.

Start the emulator debugger.


Set the operating environment

of the emulator debugger.

Set the INIT dialog box and EMEM dialog box of the emulator
debugger.


Debug a program with various functions of

the emulator debugger.

For how to use the emulator debugger, refer to the emulator
debugger’s online manual.

Figure 2.1 Flowchart of starting up the emulator

Page 19 of 98