2. Setup

REJ10J1005-0200 Rev.2.00 April 1, 2007

2.9.1 Connecting to a 100-pin LCC Socket

When connecting the emulation probe to a 100-pin LCC socket (Yamaichi Electronics Co., Ltd.: IC61-1004-051 etc.) on the

user system, following the procedure below.

(1) Attach the CN2 side of the M30850T2-EPB to the CN2 side of the M30800T-PTC.

(2) Attach the M30800T-PTC to the 100-pin LCC socket.


Figure 2.8 Connecting to a 100-pin LCC socket

CAUTION

Notes on Connecting the User System:

z Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulator.
z The small connectors of the M30850T2-EPB and M30800T-PTC are guaranteed for only 50 insertion/removal

iterations.

z For purchasing the IC61-1004-051 or for technical information, contact Yamaichi Electronics Co., Ltd.