M30850T2-EPB User’s Manual

2. Setup

REJ10J1005-0200 Rev.2.00 April 1, 2007

2.9.3 Connecting to a 100-pin 0.65mm pitch Foot Pattern (Part 2)

Figure 2.10 shows how to connect the emulation probe to a 100-pin 0.65mm pitch foot pattern on the user system with the

M3T-DIRECT100S (not included), and here following is its procedure. For details on the M3T-100LCC-DMS and M3T-

DIRECT100S, refer to each user's manual.

(1) Attach the M3T-DIRECT100S to the user system.

(2) Attach the M3T-100LCC-DMS to the M3T-DIRECT100S.

(3) Attach the M30800T-PTC to the M30850T2-EPB.

(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.

M3T-100LCC-DMS

(not included)

M3T-FLX160-EPB

M30850T2-EPB

CN2 side

(3)

(4)

M30800T-PTC

(2)

(1)

100-pin 0.65mm pitch
(PRQP0100JB-A) foot pattern

No.1 pin

User system

M3T-DIRECT100S

(not included)

Figure 2.10 Connecting to a 100-pin 0.65mm pitch foot pattern (2/3)

CAUTION

Notes on Connecting the User System:

z Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulator.
z The small connectors of the M3T-100LCC-DMS and M3T-DIRECT100S are guaranteed for only 20

insertion/removal iterations.

z The small connectors of the M30850T2-EPB and M30800T-PTC are guaranteed for only 50 insertion/removal

iterations.

Page 32 of 98