2 selecting clock supply, Important – Renesas Emulation Probe M30850T2-EPB User Manual

Page 40

Advertising
background image

M30850T2-EPB User’s Manual

2. Setup

REJ10J1005-0200 Rev.2.00 April 1, 2007

2.10.2 Selecting Clock Supply

You can choose a clock supplied to the evaluation MCU by the Emulator tab in the Init dialog box of the emulator debugger.

Table 2.4 lists the factory-settings of each clock supply.

Table 2.4 Clock supply to the MCU and default settings

Clock

Display of emulator debugger

Description

Default setting

Internal

Internal oscillator circuit

(OSC-3 or OSC-2)

Yes

External

Oscillator of user system

-

Main X

IN

-X

OUT

Generated

Internal generator circuit

(1.0 to 32.0 MHz)

-

Internal

Internal oscillator circuit

(32.768 kHz)

-

Sub X

CIN

-X

COUT

External

Oscillator of user system

Yes

IMPORTANT

Notes on Changing the Clock Supply:

z The clock supply can be set by the Init dialog box when starting up the emulator debugger or inputting CLK

command on the script window.

z For XCIN-XCOUT, it is necessary to set switches in the emulator. For details, refer to "2.10.1 Setting Switches

of Emulation Probe" (page 38).

(1) Using an Internal Oscillator Circuit Board

1) Kinds of Oscillator Circuit Boards

The PC7501 comes with an oscillator circuit board OSC-3 (30 MHz). And an oscillator circuit board OSC-3 (32 MHz)

and an oscillator circuit board OSC-2 (bare board) are included with this product. If you use the internal oscillator

circuit board OSC-3 (32 MHz) or OSC-2 of the PC7501 as a main clock, choose "Internal" in the emulator debugger

after replacing oscillator circuit boards to change a clock supplied to an MCU.

Page 40 of 98