5 connecting to a 100-pin 0.5mm pitch foot pattern, Caution – Renesas Emulation Probe M30850T2-EPB User Manual

Page 34

Advertising
background image

M30850T2-EPB User’s Manual

2. Setup

REJ10J1005-0200 Rev.2.00 April 1, 2007

2.9.5 Connecting to a 100-pin 0.5mm pitch Foot Pattern

Figure 2.12 shows how to connect the emulation probe to a 100-pin 0.5mm pitch foot pattern on the user system with the M3T-

F160-100NSD (not included), and here following is its procedure. For details on the M3T-F160-100NSD, refer to its user's

manual.

(1) Mount the NQPACK100SD included with the M3T-F160-100NSD to the user system.

(2) Attach the YQPACK100SD included with the M3T-F160-100NSD to the NQPACK100SD.

(3) Insert the YQ-GUIDEs included with the YQPACK100SD to the YQPACK100SD.

(4) Attach the M3T-F160-100NSD to the YQPACK100SD.

(5) Attach the M30850T2-EPB to the M3T-F160-100NSD.

*

M3T-FLX160-EPB

M30850T2-EPB

CN2 side

(5)

(1)

100-pin 0.5mm pitch
(PLQP100KB-A) foot pattern

No.1 pin

User system

M3T-F160-100NSD

(not included)

FLASH MCU etc.

On-board evaluation

*: These four items are available in one package.

YQPACK100SD

NQPACK100SD-ND

HQPACK100SD

(not included)

(2)

(3)

(4)

YQ-GUIDE(x4)

These corners are not round.

Figure 2.12 Connecting to a 100-pin 0.5mm pitch foot pattern

CAUTION

Notes on Connecting the User System:

z Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulator.
z The small connectors of the M30850T2-EPB and M3T-F160-100NSD are guaranteed for only 50

insertion/removal iterations.

Page 34 of 98