Power supply wiring and grounding, Connectors for hi and hip power modules, 2 power supply wiring and grounding – RuggedCom RUGGEDBACKBONE RX1510 User Manual

Page 23: 1 connectors for hi and hip power modules

Advertising
background image

RuggedBackbone™ RX1510

Installation Guide

Chapter 3

Installation

Power Supply Wiring and Grounding

17

Section 3.2

Power Supply Wiring and Grounding

The RX1510 supports dual redundant power supplies, power module 1 (PM1) and power module 2 (PM2). Power

connections are located on the PM1 and PM2 module face plates. An optional chassis ground connection is

located on the front panel as shown in

Figure 2, “Front View”

.

RX1510 products can be equipped with either a Phillips Screw Terminal Block or a Phoenix Plug Terminal

Block. The Phillips Screw Terminal Block has Phillips screws with compression plates, allowing either bare wire

connections or crimped terminal lugs. We recommend the use of #6 size ring lugs to ensure secure, reliable

connections under severe shock or vibration. Both terminal blocks have a safety cover, secured with two Phillips

screws, which must be removed to make connections. The safety cover must be re-attached after wiring to

ensure personnel safety.
For AC and DC power supply wiring examples, refer to

Section 3.2.4, “AC Power Supply Wiring ”

Section 3.2.5,

“DC Power Supply Wiring Examples”

, and

Section 3.2.6, “AC and DC Power Supply Wiring Example”

.

WARNING!

The RX1510 has two (2) power supplies installed and may be supplied from multiple power sources.

Service personnel must isolate all power supplies prior to servicing.

Section 3.2.1

Connectors for HI and HIP Power Modules

Figure 37: Screw Terminal Power

Connector for HI Power Module

Figure 38: Pluggable Phoenix Power

Connector for HIP Power Module