EMI And Environmental Type Tests

RuggedBackbone™ RX1510

Installation Guide

40

Test

Description

Test Levels

Severity

Levels

A.C. Power ports

2.5kV common, 1kV

diff. mode@1MHz

3

Signal ports

30V Continuous, 300V for 1s

4

IEC 61000-4-16

Mains Frequency Voltage

D.C. Power ports

30V Continuous, 300V for 1s

4

IEC 61000-4-17

Ripple on D.C.

Power Supply

D.C. Power ports

10%

3

Signal ports

2kVAC (Fail-Safe Relay output)

N/A

D.C. Power ports

1.5kVDC

N/A

IEC 60255-5

Dielectric Strength

A.C. Power ports

2kVAC

N/A

Signal ports

5kV (Fail-Safe Relay output)

N/A

D.C. Power ports

5kV

N/A

IEC 60255-5

H.V. Impulse

A.C. Power ports

5kV

N/A

a

RuggedCom-specified severity levels

Table 26: IEEE 1613 (C37.90.x) EMI Immunity Type Tests

b

Test

Description

Test Levels

Enclosure Contact

+/-2kV, +/-4kV, +/- 8kV

IEEE C37.90.3

ESD

Enclosure Air

+/-4kV, +/-8kV, +/-15kV

IEEE C37.90.2

Radiated RFI

Enclosure ports

35 V/m

Signal ports

+/- 4kV @ 2.5kHz

D.C. Power ports

+/- 4kV

A.C. Power ports

+/- 4kV

IEEE C37.90.1

Fast Transient

Earth ground ports

+/- 4kV

Signal ports

2.5kV common mode @1MHz

D.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

IEEE C37.90.1

Oscillatory

A.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

Signal ports

5kV (Fail-Safe Relay output)

D.C. Power ports

5kV

IEEE C37.90

H.V. Impulse

A.C. Power ports

5kV

Signal ports

2kVAC

D.C. Power ports

1.5kVDC

IEEE C37.90

Dielectric Strength

A.C. Power ports

2kVAC

b

Meets Class 2 requirements for an all-fiber configuration. Meets Class 1 requirements for copper ports.

Table 27: Environmental Type Tests

Test

Description

Test Levels

IEC 60068-2-1

Cold Temperature

Test Ad

-40°C, 16 Hours

Advertising