M301N2T-PRB User’s Manual

5. Troubleshooting

REJ10J0037-0100 Rev.1.00 Mar.16, 2005

Page 40 of 48

5. Troubleshooting


This chapter describes how to troubleshoot when this product does not work properly.

5.1 Flowchart to Remedy the Troubles


Figure 5.1 shows the flowchart to remedy troubles from when power to the emulator is activated until the emulator debugger
starts up. Check this while the user system is not connected. For the latest FAQs visit the Renesas Tools Homepage.

http://www.renesas.com/en/tools

Turning on the power of PC4701

Not normal

PC4701 Front panel LEDs

1. Check emulator system connections.

See "2.4 Connecting the M30100T3-RPD-E" (page 22).

2. Redownload the firmware.

See "3.3 Downloading Firmware" (page 28).

3. Restart the PC4701 system.

Not normal or error displayed

Init dialog box of emulator debugger

displayed

1. Check the operating environment etc. of the emulator

debugger.
See the emulator debugger user's manual (online
manual).

2. Reinstall the emulator debugger.

Error

displayed

See "5.2.2 Emulator Debugger Does Not Starts Up Properly

(Target Connected)" (page 42).

See "5.2.3 Emulator Debugger Does Not Starts Up Properly

(Target Not Connected)" (page 43).

Emulator debugger starts up properly

Figure 5.1 Flowchart to remedy troubles