M301N2T-PRB User’s Manual

5. Troubleshooting

REJ10J0037-0100 Rev.1.00 Mar.16, 2005

Page 41 of 48


5.2 When the Emulator Debugger Does Not Start Up Properly

5.2.1 When the LED Display of the PC4701 is Abnormal

Table 5.1 LED's abnormal display and its checkpoints

Error

Connection to

the user

system

Checkpoint

LEDs do not light up.

-

Check that the power cable is connected to the PC4701.
See the PC4701 user's manual

All LEDs remain lit.

-

Check the connection between the PC4701 and this product.
See "2.4 Connecting the M30100T3-RPD-E" (page 22)
See the M30100T3-RPD-E user’s manual

The "POWER" LED of "STATUS
OF TARGET" does not light up.

Connected

Check that power (Vcc and GND) is properly supplied to the
user system.

Disconnected

(1) Check that both the main/sub clocks are not set to

“External” in the emulator debugger..
See the CLK command of the emulator debugger

(2) Check the oscillator circuit board is mounted in the

M30100T3-RPD-E and it is oscillating properly.

See the M30100

T3

-RPD-E user’s manual

The "CLOCK" LED of "STATUS
OF TARGET" does not light up.

Connected

(1) When the clock supply is set to “External”, check that the

oscillation circuit on the user system is oscillating
correctly.

(2) Check the switches in the M30100T3-RPD-E are correctly

set.
See “2.2 Switch settings” (page 20)

The "RESET" LED of "STATUS
OF TARGET" does not go out.

Connected

Check the reset pin of the user system is held high.

Advertising