Configuration problems

In case your SpeedTouch™ is unreachable due to misconfiguration, you might consider
a hardware reset to factory defaults as described in

“4.3 Resetting the SpeedTouch™”

on page 52

.

Troubleshooting table

Following table may help you determine the nature of the problem, and provides some
plausible solutions:

Problem

Solution

SpeedTouch™ does not work.
(none of the LEDs light up)

Make sure that the SpeedTouch™ is plugged
into an power socket outlet.

Make sure that you are using the correct
power supply for your SpeedTouch™ device.

Make sure the power button on the Speed-
Touch™ is pushed in.

LAN LED does not light up.
Link integrity/Activity LED of
Ethernet port does not light up.

Make sure that the Ethernet cable is securely
connected to the 10/100Base-T port.

Make sure that you are using the correct
cable type for your Ethernet equipment.

No Line synchronization achieved.
DSL LED off or flashing.

Check whether the central splitter or dedi-
cated filters are installed correctly and that
the correct line is patched to your Speed-
Touch™ line port.

Make sure that ADSL service is enabled on
the telephone line the SpeedTouch™ is
connected to.

In case of ADSL/POTS (ADSL/PSTN)
services at your premises, ONLY use a
SpeedTouch™ ADSL/POTS variant.


In case of ADSL/ISDN services at your local
premises, ONLY use a SpeedTouch™ ADSL/
ISDN variant.

Bad regular telephone service

Check whether a central splitter or dedi-
cated filters are installed properly.