Raypak XPAK 85 User Manual

Page 44

Advertising
background image

44

Fig. 45

A

Pressure gauge

B

Green led

C

2-digit LED display

D

Red led

E

Temperature selector space heating

F

Mode selector switch

G

Temperature selector Domestic Hot Water*

* The parts of the manual refering to the DHW circuit should be only considered if a indirect water tank with sensor is installed, case B (Fig. 61)

A

B

C

D

E

F

G

Domestic hot water (with connection to an external water tank
with probe)
The function starts if the temperature measured by the water tank
probe falls below 40°F (4°C). In this mode, a heat demand is
generated and the burner ignites at minimum power. This is
maintained until the temperature of the delivery water reaches
95°F (35°C).

NOTICE:

During the freeze protection mode, AF flashes on

the display (Fig. 56)
- circulator anti-block: if the boiler remains inactive, the

circulator performs a 30-second operating cycle every 24
hours. If the boiler is planned not to be used for a long
period, proceed as follows:

- move the function selector to OFF-RESET
- turn the main system switch to “off”

8. INDICATOR LEDS AND FAULTS

Green indicator LED (Fig. 52)
Off = boiler on stand-by, no flame
On = burner on, the boiler works regularly.

Red indicator LED (Fig. 53)
Stop:
just the fault code flashes on the digital display.
Block: the red indicator LED lights up and the fault code flashes
on the digital display.

The fault code is not displayed in the OFF/RESET (

) mode. To

display it, move the function selector to

,

or

F

. During

combustion analysis and the freeze protection mode, instead, it is

displayed. To reset the boiler, turn the function selector to

(OFF/

RESET) and then move it to be required position (Fig. 47). If the
boiler still doesn’t work, call in the local Service Technician.