VOYAGEUR GRAND Wood Insert

H. Air Controls

1. Start-Up Air Control
The function of the Start-Up Air Control is to activate the

Automatic Combustion Control system (ACC).
• Push the Start-Up Air Control all the way back until it stops

and then pull forward to the front of the appliance until it

stops.

Figure 10.1.

• The air channel opens and allows air to enter the front of

the appliance for approximately 20-25 minutes.

• The air channel gradually shuts down until it is completely

closed at the end of the 20-25 minutes.

• The fire is now controlled by the air supplied by the Burn

Rate Air Control.

Figure 10.1.

• This function should be performed each time you reload

the appliance.

Figure 10.1 Start-up and Burn Rate Air Controls

2. Burn Rate Air Control

The air supply enters at the upper front of the firebox,

near the top of the glass door.

This preheated air supplies the necessary fresh oxygen

to mix with the unburned gases, helping to create the

second, third and fourth combustion process.

• This air is regulated by the Burn Rate Air Control.

There are four settings High, Medium-High, Medium-Low

and Low.

When the control is raised all the way up it is on the High

setting and when pushed all the down it is on the Low

setting.

G. Automatic Combustion Control (ACC)

Typically, when you build a fire, you open the air controls fully

and monitor the fire to prevent it from going into an overfire

situation and/or burning your wood up too quickly before you

shut down the air controls to the desired burn rate.
When using the Automatic Combustion Control (ACC) system,

you do not have to continually monitor the fire. Once you

set the ACC system it will control the fire for you. Follow the

instructions below to learn how to operate your stove with

ease.

I. Burn Rates and Operating Efficiency

For maximum operating efficiency
1. Burn dry, well-seasoned wood.
2. Follow these burn rate instructions below and refer to

Figure 10.1.

*NOTE: These are guidelines. Actual settings may vary with type

of wood, chimney draft, altitude and other variables.

Burn Rates
1. Starting a Fire and Reloading

Open both controls fully by raising the Burn Rate Air Con-

trol all the way up until it stops and push the Start-up Air

Control back until it stops.

• The blower tends to cool the appliance. Leave the blower

off until the burn is well established, i.e., 30 minutes.

After loading the appliance with wood and starting the fire,

set both controls to the desired setting by following the

burn rate instructions below.

2. High Burn Rate - Maximum Heat*

• Raise the Burn Rate Air Control all the way up until it stops

(top marker) to a fully open position.

Push the Start-Up Air Control all the way back until it stops

and leave it there.

• This setting over-rides the timer system (ACC) so you must

monitor the fire closely while in this setting.

3. Medium-High Burn Rate

-

15,000 to 30,000 BTU/hr*

Raise the Burn Rate Air Control all the way up until it stops

to a fully open position.

Push the Start-Up Air Control all the way back until it stops

and then pull forward until it stops.

• This activates the timer system (ACC).

4. Medium-Low Burn Rate - 10,000 to 15,000 BTU/hr*

• Raise the Burn Rate Air Control up 1/4 from lowest posi-

tion.

Push the Start-Up Air Control all the way back until it stops

and then pull forward until it stops.

• This activates the timer system (ACC).

5. Low Burn Rate - Below 10,000 BTU/hr*

• Leave the Burn Rate Air Control at its lowest position.

Push the Start-Up Air Control all the way back until it stops

and then pull forward until it stops.

• This activates the timer system (ACC).

Burn Rate Control

ACC Start-up

Air Control

HIGH

LOW

To activate: Push back until it stops

and then pull forward until it stops