VOYAGEUR GRAND Wood Insert

Ovalizing round stainless steel liners to accommodate the

liner passing through the damper region of a fireplace is an

allowable and acceptable practice.
Ensure that the ovalization is minimized to the extent

required to fit through the damper.

J. Ovalizing Round Stainless Steel Liners

Fire Risk.
Do NOT pack insulation or other combustibles

between spacers.
• ALWAYS maintain specified clearances around

venting and spacers.

• Install spacers as specified.
Failure to keep insulation or other material away from

vent pipe may cause fire.

WARNING

K. Chimney Height / Rise and Run

To be sure that your Quadra-Fire insert burns properly, the

chimney draft (static pressure) should be approximately -0.10

inches water column (W.C.) during a high burn and -0.04

inches W.C. during a low burn, measured 6 inches (152mm)

above the top of the insert after one hour of operation at each

burn setting.

NOTE: These are guidelines only, and may vary somewhat

for individual installations.

• This product was designed for and tested on a 6 inch

(152mm) chimney, 14 to 16 feet (4.27-4.87m) high, (in-

cludes appliance height) measured from the base of the

appliance.

• The further your stack height or diameter varies from this

configuration, the possibility of performance problems ex-

ists.

• Chimney height may need to be increased by 2 - 3% per

each 1000 feet (304.8m) above sea level.

• It is not recommended to use offsets or elbows at altitudes

above 4000 feet (1219.2m) above sea level or when there

are other factors that affect flue draft.

Fire Risk.
This appliance relies upon natural draft to operate

properly.
• Chimney heights exceeding 25 feet (7.62m) from

base of appliance may create an over-draft situation.

• Overdraft condition may create over-firing.
Over-firing may ignite creosote and/or damage appli-

ance and chimney.

WARNING

Fire Risk.
Failure to install a full reline may cause:
• Creosote accumulation creating increased risk of

chimney fire.

• Lose protection to combustible surfaces from the

liner in case of fire.

• Poor performance and start-ups.
• Less access to chimney for required maintenance.

WARNING