Caution, Warning, Mobile home installation – Radware VOYAGEUR GRAND WOOD INSERT VOYA-GRAND-MBK User Manual

Page 46

Advertising
background image

Page 46

7075-166C

May 23, 2013

R

VOYAGEUR GRAND Wood Insert

Figure 47.1

NOTICE:
Offsets from the vertical, not exceeding 45°, are allowed

per Section 905(a) of the Uniform Mechanical Code

(UMC).

Offsets greater than 45° are considered horizontal and are

also allowed, providing the horizontal run does not exceed

75% of the vertical height of the vent.

Construction, clearance and termination must be in com-

pliance with the UMC Table 9C. This installation must also

comply with NFPA 211.

NOTICE: Top sections of chimney must be removable to allow

maximum clearance of 13.5 feet (411cm) from ground level

for transportation purposes.

1. An outside air inlet must be provided for combustion and

must remain clear of leaves, debris, ice and/or snow. It

must be unrestricted while unit is in use to prevent room

air starvation which can cause smoke spillage and an

inability to maintain a fire. Smoke spillage can also set

off smoke alarms.

2. Unit must be secured to the mobile home structure.

Remove bolts from each side of insert and use plumbers

tape to secure to structure (a washer may be required).

Re-install bolts.

3. Unit must be grounded with #8 solid copper grounding

wire or equivalent and terminated at each end with N.E.C.

approved grounding device.

4. The factory-built fireplace must meet (UM)84-HUD

requirements for outside combustion air supply to the

fireplace fire chamber and the chimney must be listed to

UL103 HT or a listed UL-1777 full length six inch (152mm)

diameter liner must be used. It must be equipped with a

spark arrestor cap and the outside air must be installed

on the insert.

5. Refer to

page 31 of this manual for clearance to

combustibles and floor protections requirements.

All

clearances must be followed precisely.

6. Use silicone to create an effective vapor barrier at the

location were the chimney or other component penetrates

to the exterior of the structure.

7. Follow the chimney and chimney connector manufacturer’s

instructions when installing the flue system for use in a

mobile home.

8. Burn wood only. Other types of fuels may generate

poisonous gases (e.g., carbon monoxide).

9. If unit burns poorly while an exhaust blower is on in home,

(i.e., range hood), increase combustion air.

10. Installation shall be in accordance with the Manufacturers

Home & Safety Standard (HUD) CFR 3280, Part 24.

Spark Arestor Cap

Roof Flashing

Storm Collar

Joist Shield/Firestop

Double Wall

Connector Pipe

CAUTION

THE STRUCTURAL INTEGRITY OF THE MOBILE HOME

FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED

Do NOT cut through:

• Floor joist, wall, studs or ceiling trusses.

Any supporting material that would affect the structural integ-

rity.

• NEVER INSTALL IN A SLEEPING ROOM.
Consumes oxygen in the room.

WARNING

Asphyxiation Risk.

WARNING

Do not draw outside combustion air from:

• Wall, floor or ceiling cavity

• Enclosed space such as an attic or garage
• Close proximity to exhaust vents or chimneys.
Fumes or odor may result

Fire Risk.
Asphyxiation Risk.

10

Mobile Home Installation