EXP1, EXP2: Compared to Linear, a wider volume change

will occur for stronger hits.

fig.08-06be

LOG1, LOG2: Compared to Linear, wider volume change

will occur for softer hits.

fig.08-06ce

Spline: Variation in striking force will produce extreme

change.

fig.08-06de

Loud1, Loud2: Variation in striking force will produce little

change, and a constant volume will be main-
tained. When using drum triggers, these set-
tings help maintain stable levels.

fig.08-06ee

Head Tension Adjustment

The Head Tension Adjustment parameter regulates the fol-
lowing two adjustments for the PD-100 and PD-120. Press
[SETUP]-[F1 (TRIG)]-[F4 (OPTION)] and the setting page
will appear.

* The setting page for this setting will appear only if the Trigger

Type (p. 108) is set to “10A” or “12A” for trigger number 2
(SNARE) and trigger number 10 (RIDE).

Adjust the head to an even tension

This setting allows the strike location to be accurately detect-
ed. For the procedure refer to p. 31.

Adjust the tension of the head

Adjusting the Head Tension Adjustment value to the stan-
dard value of “Normal” will provide an average head ten-
sion. If you wish to loosen this, select “Loose.” To tighten it,
select “Tight.” Then refer to the procedure of p. 32. and
adjust the tension.

* Unlike tuning an acoustic drum, this setting will not affect the

pitch. It affects only the tension of the head. But this is VERY
important to achieve the best results for positional sensing, and
to make sure that the head tension is even. For tuning the pitch
of the sound, refer to p. 82.

Parameters

Head Tension Adjustment: Loose, Normal, Tight

Rim Sensitivity

When a PD-120 is used with trigger number 2 (SNARE), you
can adjust the sensitivity of the rim. Higher settings will
increase the sensitivity of the rim. With a setting of Off, only
the head will sound.

Procedure

1.

Set the trigger type to “12A.”

For this setting, refer to p. 108.

2.

Press [SETUP]-[F1 (TRIG)]-[F4 (OPTION)].

The “TRIGGER OPTION” page will appear.

3.

Use [CURSOR] to move the cursor to “Rim Sensitivity.”

4.

Use [INC/DEC] or the VALUE dial to make the setting.

Parameters

Rim Sensitivity: Off, 1–15

* Increasing the value excessively may cause the rim instrument

to sound as well when the head is struck.

EXP1

EXP2

striking force

loudness

LOG2

LOG1

striking force

loudness

Spline

striking force

loudness

Loud1

Loud2

striking force

loudness

Chapter 7. Settings for the entire TD-10