Program Change

Status

2nd byte

CnH

ppH

n = MIDI channel number:

0H - FH (ch.1 - ch.16)

pp = Program number:

00H - 7FH (prog.1 - prog.128)

*

When a drum kit is selected, or when a pattern is selected, the pattern number of the
sequencer pattern data will be transmitted.

Pitch Bend Change

Status

2nd byte

3rd byte

EnH

llH

mmH

n = MIDI channel number:

0H - FH (ch.1 - ch.16)

mm,ll = Pitch Bend value:

00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191)

*

Transmitted only when the TD-10 is in play for Pattern in which Pitch Bend Change is
recorded.

System Common Messages

Song Position Pointer

Status

2nd byte

3rd byte

F2H

llH

mmH

mm,ll = Song Position:

F00 00H - 7F 7FH(0 - 16383)

Song Select

Status

2nd byte

F3H

ppH

pp = Pattern number:

00H-63H (PATTERN1-PATTERN100)

*

When a pattern is selected, the song select number will be transmitted.

System Realtime Message

Timing Clock

Status
F8H

Start

Status
FAH

Continue

Status
FBH

Stop

Status
FCH

Active sensing

Status
FEH

*

This will be transmitted constantly at intervals of approximately 250ms.

System exclusive messages

Inquiry reply and Data Set 1 (DT1) are the only System Exclusive messages transmitted by
TD-10.
When an appropriate “Inquiry Request” or “Data Request 1 (RQ1)” message is received,
the requested internal data will be transmitted.

Universal Non-realtime System Exclusive Messages

Inquiry reply

Status

Data byte

Status

F0H

7EH, dev, 06H, 02H,41H,0AH,01H,00H,00H,00H,

F7H

06H,00H,00H

Byte

Explanation

F0H

Exclusive status

7EH

ID number (universal non-realtime message)

dev

Device ID (dev: 00H - 1FH (1 - 32) Initial value is 10H (17))

06H 02H

Inquiry reply

41H

ID number(Roland)

0AH 01H

Device family code

00H 00H

Device family number code

00H 02H 00H 00H

software revision level

F7H

EOX (End Of Exclusive)

*

When Inquiry Request (P. 156)is received, Inquiry Reply message will be transmitted.

Data set 1

DT1 (12H)

Status

Data byte

Status

F0H

41H, dev, 00H, 0AH, 12H, aaH, bbH, ccH, ddH,

F7H

eeH,... ffH, sum

Byte

Explanation

F0H

Exclusive status

41H

ID number (Roland)

dev

Device ID (dev: 00H - 1FH Initial value is 10H)

00H 0AH

Model ID (TD-10)

12H

Command ID (DT1)

aaH

Address MSB: upper byte of the starting address of the data to be sent

bbH

Address 2nd: 2nd byte of the starting address of the data to be sent

ccH

Address 3rd: 3rd byte of the starting address of the data to be sent.

ddH

Address LSB: lower byte of the starting address of the data to be sent.

eeH

Data: the actual data to be sent. Multiple bytes of data are transmitted in
order starting from the address.

:

:

ffH

Data

sum

Checksum

F7H

EOX (End Of Exclusive)

*

The amount of data that can be transmitted at once time will depend on the type of
data, and data must be requested using a specific starting address and size. Refer to the
Address and Size listed in 3.Parameter address map (Page 159).

*

Data larger than 128 bytes must be divided into packets of 128 bytes or less. If “Data Set
1” is transmitted successively, there must be an interval of at least 40 ms between pack-
ets.

*

Regarding the checksum please refer to Page 163.

Bulk Dump

Bulk Dump allows you to transmit a large amount of data at once, and is convenient for
storing settings for the entire unit on a computer or sequencer.
For Bulk Dump Request, you must use the Address and Size listed in the following “Bulk
Dump Request.”

Bulk Dump Request

Address(H)

Size(H)

10 00 00 00

00 00 00 00 (ALL Patterns: dump request for all user pattern (51-100))

40 00 00 00

01 00 00 00 (SETUP: )

41 nn 00 00

00 01 00 00 (DRUM KIT:)

44 pp 16 00

00 00 48 00 (PERCUSSION GROUP:)

mm = 01-32H (Pattern No.51-100)
nn = 00-31H (Drum Kit No.1-50)
pp = 00-03H (Perc Group No.1-4)

*

Request for ALL PATTERNS and SET UP are correspond to “Bulk Dump” parameter (
[SETUP]-[F2(MIDI)]-[F4(BULK)]).

*

Data of preset pattern (No.1-50) cannot be transmitted.

MIDI implementation