INSTALLATION

Check the ap pli ance is electrically safe and gas sound when you have fi nished.

Screw connect the threaded end of the hose into the gas
inlet in the underside of the connector block on the back
of the cooker.

After completing the gas connection, check the cooker
is gas sound with a pressure test. When checking for gas
leaks do not use washing up liquid - this can corrode.
Use a product specifi cally manufactured for leak
detection.

Pressure testing

The gas pressure can be measured at one of the centre
hotplate burner injectors (not the Wok burner). Lift off a
burner head. Fit the pressure gauge to the injector. Turn
on and light one of the other hotplate burners. Turn on
the control knob for the burner with the pressure gauge
fi tted to let gas through.

Pressures

Natural Gas

LP Gas cookers

20mbar.

Butane

29mbar

Propane

37mbar

Turn off the burners. Reassemble burner top, making
sure it is re as sem bled in the correct way on the burner
body.

Electrical Connection

This appliance must be installed by a qual i fi ed electrician
to comply with the relevant In sti tute of Electrical
Engineers (I.E.E.) regulations and also the local elec tric i ty
supply company re quire ments.

WARNING: THIS APPLIANCE MUST BE EARTHED

Note

The cooker must be connected to the cor rect electrical
supply as stated on the voltage la bel on the cooker,
through a suitable cooker control unit incorporating
a double pole switch having a contact separation
of at least 3mm in all poles. This cooker must not be
connected to an ordinary domestic power point.

Access to the mains terminal is gained by re mov ing the
electrical terminal cover on the back panel.