WARNING  SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON

Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.

Conversion to LP gas

Check in the Technical Data section at
the back of the book that the cooker is
convertible to the gas you want to use.

This conversion must be performed by a competent
person. After conversion the installation must comply
with the relevant regulations and also the local
electricity supply company requirements. Read the
instructions before converting this appliance.

Failure to convert the appliance correctly could
invalidate any warranty or liability claims and lead to
prosecution.

This instruction must be used in conjunction with
the rest of the appliance in struc tion, in particular
for information on Standards, cooker positioning,
connection hose suitability etc.

When servicing or replacing gas-carrying
components disconnect from gas before
commencing operation and check appliance is gas
sound after completion.

Do not use re-conditioned or unauthorised gas
controls.

Disconnect from the electricity supply before
commencing servicing. Before electrical re-
connection, check that the appliance is electrically
safe.

Injectors

Remove burner caps and heads. Remove old jets. Fit the
new jets (see Technical Data section at the back of the
book for correct jets). Reassemble in reverse order.

Tap adjustment

Disconnect from electricity supply.

Pull off all the control knobs.

Open the grill and right hand oven doors and remove
the 4 fi xing screws underneath the control panel.

The control panel should drop down slightly. It is held
at the top by two holes in the top edge one at each end
that locate on tags on the inner panel.

Clear the holes from the inner panel and pull the control
panel forward.

Take care not to damage or strain the wiring.

To convert to LP gas.

Unscrew the tap bypass screw.

Using a pair of long nose pliers carefully remove the
bypass screw and fi t the correct replacement screw.
See the table for the correct size. Tighten the screw
down.

Refi t the control panel. Locate the holes in the top edge
on the tags on the inner panel and replace the fi xing
screws in the bottom edge.

Replace the hand rail.

Stick on label

Stick the LP gas label over the natural gas part of the
appliance data label.