Installation – solar storage tank, Solar water heater storage tank location – Rheem GAS BOOSTED SOLAR WATER HEATER User Manual

Page 17

Advertising
background image

17

INSTALLATION – SOLAR STORAGE TANK


THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY.
THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING.
Check the water heater is suitable for the gas type available.
(refer to the rating label on the water heater)

The system is suitable for installation with Solahart ‘J’ or ‘KF’ solar collectors.

The solar circuit must be installed with a continuous fall of a minimum 5° in the pipe work from the solar
collectors to the solar storage tank, the solar hot and solar cold pipes must be fully insulated with closed
cell polymer insulation (minimum thickness 13 mm) and the system charged with correctly mixed closed
circuit fluid to offer protection against freeze damage. The system has NO WARRANTY for freeze
damage if there is not a continuous fall in the solar hot and solar cold pipes or they are uninsulated or
the closed circuit fluid has been incorrectly mixed (refer to

“Warranty Exclusions”

on page 53).

SOLAR WATER HEATER STORAGE TANK LOCATION
The solar storage tank is suitable for outdoor installation only. The solar storage tank should be
installed close to the most frequently used outlet and its position chosen with safety and service in
mind. Make sure people (particularly children) will not touch the flue terminal. The flue terminal and air
inlet must be clear of obstructions and shrubbery.

Consideration must also be given to the position of the solar storage tank in relation to the solar
collectors. There are limitations on both the maximum length of the solar hot and solar cold pipes and
the maximum height between the solar storage tank and the solar collectors. Refer to

“Solar Collector

Location”

on page 26 and to

“Pipe Lengths”

on page 27.


Clearance must be allowed for servicing of the solar
storage tank and gas booster. The solar storage tank
must be accessible without the use of a ladder or
scaffold. Make sure the temperature pressure relief
valve lever is accessible and the front panel and front
covers can be removed for service.

You must be able to read the information on the rating
plate. If possible leave headroom of one water heater
length so the anode can be inspected or replaced.
Remember you may have to remove the entire solar
storage tank later for servicing.

The installation must comply with these installation
instructions and with the requirements of
AS/NZS 3500.4, AS 5601, AS/NZS 3000 and all local
codes and regulatory authority requirements. In New
Zealand, the installation must conform with the New
Zealand Building Code.

The water heater must not be installed in an area with a corrosive atmosphere where chemicals are
stored or where aerosol propellants are released. Remember the air may be safe to breathe, but when
it goes through a flame, chemical changes take place which may attack the water heater.

It is recommended the solar storage tank be installed at ground or floor level and must stand vertically
upright.

Note: It is important for the solar storage tank to be orientated vertically upright in order for the falling
film of closed circuit fluid to operate efficiently.

A secondary flue is not required. The water heater must not be installed indoors or in a confined space.